NRAO Home > CASA > CASA Task Reference Manual

0.1.34 gencal

Requires:

Synopsis
Specify Calibration Values of Various Types

Description

Specify calibration externally.



Arguments





Inputs

vis

Name of input visibility file

allowed:

string

Default:

caltable

The new/existing calibration table

allowed:

string

Default:

caltype

The calibration type: ’amp’,’ph’,’sbd’,’mbd’,’antpos’,’antposvla’,’tsys’,’evlagain’,’opac’,’gc’,’gceff’,’eff’,’tecim’

allowed:

string

Default:

infile

Input ancilliary file

allowed:

string

Default:

spw

Calibration spw(s) selection

allowed:

string

Default:

antenna

Calibration antenna(s) selection

allowed:

string

Default:

pol

Calibration polarizations(s) selection

allowed:

string

Default:

parameter

The calibration values

allowed:

doubleArray

Default:

Returns
void

Example

 
 
     The gencal task provides a means of specifying antenna-based  
     calibration values manually.  The values are put in designated  
     tables and applied to the data using applycal.  Several  
     specialized calibrations are also generated with gencal.  
 
     Current antenna-based gencal options (caltype) are:  
        ’amp’= amplitude correction  
        ’ph’ = phase correction  
        ’sbd’= single-band delay (phase-frequency slope for each spw)  
        ’mbd’= multi-band delay (phase-frequency slope over all spw)  
        ’antpos’ = ITRF antenna position corrections  
        ’antposvla’ = VLA-centric antenna position corrections  
        ’tsys’ = Tsys from the SYSCAL table (ALMA)  
        ’swpow’ = EVLA switched-power gains (experimental)  
        ’evlagain’ (=’swpow’) (this syntax will deprecate)  
        ’rq’ = EVLA requantizer gains _only_  
        ’swp/rq’ = EVLA switched-power gains divided by requantizer gain  
        ’opac’ = Tropospheric opacity  
        ’gc’ = Gain curve (zenith-angle-dependent gain) (VLA only)  
        ’eff’ = Antenna efficiency (sqrt(K/Jy)) (VLA only)  
        ’gceff’ = Gain curve and efficiency (VLA only)  
        ’tecim’ = Time-dep TEC image specified in infile  
 
     Generic calibration parameters should be specified in the ’parameter’  
     argument as a list.  The length of the list must correspond  
     to the net length of the specific polarizations, antennas, and  
     spws specified in the selection arguments.  The specified  
     parameters will be duplicated over all members of any unspecified  
     selection axes.  E.g., if pol=antenna=spw=’’, it only makes  
     sense to specify a single parameter value, and this will be  
     duplicated for all pols, antennas, and spws.  If multiple  
     parameter values are specified, at least one of the selection  
     arguments must be non-trivial, and the number of specified  
     parameters must be consistent with the explicit selection.  
     E.g., if a non-trivial spw selection is specified, then the  
     parameter list should match the number of spws specified, and  
     these values will be duplicated for all polarizations and  
     antennas.   If more than one selection argument is non-trivially  
     specified, the number of parameters specified should match  
     the product of the number specified selection elements.  The  
     parameter values should be sorted by pol (fastest), antenna, and  
     spw (slowest).   Un-specified elements on non-trivially specified  
     axes will be filled with nominal values (i.e., it is not  
     necessary to exhaustively specify all elements on any axis or  
     use nominal parameter values explicitly).  Please consult the  
     examples provided below for additional guidance.  There is  
     currently no support for time-dependent parameter specfication.  
     The specified parameters will be assumed constant in  
     time (though their impact on the data may be time-dependent,  
     depending on the caltype).  Some caltype options do not require  
     parameter specifications; these are described in detail below.  
 
     The same caltable can be specified for multiple runs of gencal,  
     in which case the specified parameters will be incorporated  
     cumulatively.  E.g., amplitude parameters (caltype=’amp’)  
     multiply and phase-like parameters (’ph’, ’sbd’,’mbd’,’antpos’)  
     add.  ’amp’ and ’ph’ parameters can be incorporated into the  
     same caltable (in separate runs), but each of the other types  
     require their own unique caltable.   A mechanism for  
     specifying manual corrections via a text file will be provided in  
     the future.  
 
     The caltables are applied to the data by using applycal.  Other  
     calibration tables may also be present, if applicable.  
 
     For antenna position corrections (caltype=’antpos’), the antenna  
     position offsets are specified in the ITRF frame. For EVLA, automated  
     lookup of the antenna position corrections is enabled when antenna is  
     unspecified (antenna=’’) for this caltype. Note that this requires  
     internet connection to access the EVLA antenna position correction  
     site.  
     For VLA position corrections in the VLA-centric frame, use  
     caltype=’antposvla’, and gencal will rotate them to ITRF before  
     storing them in the output caltable.  
 
     For Tsys (caltype=’tsys’, for ALMA) and EVLA switched power  
     corrections (caltype=’swpow’), the calibration parameters are  
     derived from information contained in MS subtables.  In these  
     cases, specification of spw, antenna, pol, and parameter will be  
     ignored.  
 
     EVLA switched power calibration is supported in three modes:  
     ’swpow’ (formerly ’evlagain’, a syntax which will  
       deprecate) yields the formal EVLA switched power calibration  
       which describes voltage gain as sqrt(Pdif/Tcal) (used to  
       correct the visibility data) and Tsys as Psum*Tcal/Pdif/2 (used  
       to correct the weights).  ’swpow’ implicitly includes any  
       requantizer gain scale and adjustments.  
     ’rq’ yields only the requantizer voltage gains (Tsys is set to  
       1.0 to avoid weight adjustments).  
     ’swp/rq’ yields the ordinary switched power voltage gains divided  
       by the requantizer voltage gain (Tsys is calculate normally).  
     The ’rq’ and ’swp/rq’ modes are are mainly intended for testing  
     and evaluating the EVLA switched power systems.  
 
     For caltype=’opac’, specify the desired opacity(ies) in the parameter  
     argument.  At this time, only constant (in time) opacities are  
     supported via gencal.  
 
     For gaincurve and efficiency (caltype=’gc’, ’gceff’, or ’eff’),  
     observatory-provided factors are determined per spw according  
     to the observing frequencies.  The parameter argument is  
     ignored.  These caltypes are currently only supported  
     for VLA processing.  (Appropriate factors for ALMA are TBD.)  
 
     Keyword arguments:  
 
     vis -- Name of input visibility file  
             default: none.  example: vis=’ngc5921.ms’  
     caltable -- Name of input/output caltable.  If it does not  
                  exist, it will be created.  Specifying an  
                  existing table will result in the parameters  
                  being applied cumulatively. Only a single  
                  time-stamp for all calibrations are supported,  
                  currently.  Do not use a caltable  
                  created by gaincal, bandpass, etc.  
                  default: none.  example: caltable=’test.G’  
     caltype -- The calibration parameter type being specified.  
                 Options include:  
                 ’amp’ = gain (G) amplitude (1 real parameter per  
                         pol, antenna, spw)  
                 ’ph’  = gain (G) phase (deg) (1 real parameter per  
                         pol, antenna, spw)  
                 ’sbd’ = single-band delays (nsec) (1 real parameter  
                         per pol, antenna, spw)  
                 ’mbd’ = multi-band delay (nsec) (1 real parameter  
                         per pol, antenna, spw)  
                 ’antpos’ = antenna position corrections (m) (3 real  
                            ITRF offset parameters per antenna; spw, pol  
                            selection will be ignored)  
                            With antenna=’’, this triggers an automated lookup  
                            of antenna positions for EVLA.  
                 ’antposvla’ = antenna position corrections (m) specified  
                               in the old VLA-centric coordinate system  
                 ’tsys’ = Tsys from the SYSCAL table (ALMA)  
                 ’evlagain’ = EVLA switched-power gains (experimental)  
                 ’opac’ = Tropospheric opacity (1 real parameter  
                         per antenna, spw)  
                 ’gc’ = Antenna zenith-angle dependent gain curve (auto-lookup)  
                 ’gceff’ = Gain curve and efficiency (auto-lookup)  
                 ’eff’ = Antenna efficiency (auto-lookup)  
                 default: none.  
                 example: caltype=’ph’  
     spw -- Spectral window selection for specified parameters.  
             default: spw=’’ (specified parameters apply to all spws)  
             example: spw = ’2,3,4’  
     antenna -- Antenna selection for specified parameters.  
                 default: antenna=’’ (specified parameters apply to all antennas)  
                 example: antenna=’ea02, ea03’ (specified parameter(s) to  
                           apply to ea02 and ea03 only)  
     pol -- Polarization selection for specified parameters.  
             default: pol=’’ (specified parameters apply to all polarizations)  
             example: pol=’R’ (specified parameters to apply to  
                                 R only)  
     parameter -- The calibration parameters, specified as a list, to  
                   store in the caltable for the spw, antenna, and pol  
                   selection.  The required length of the list is  
                   determined by the caltype and the spw, antenna, pol  
                   selection.  One "set" of parameters (e.g., one value  
                   for ’amp’, ’ph’, etc., three values for ’antpos’)  
                   specified the same value for all indicated spw, antenna,  
                   and pol.  
                   OR,  
                   When specifying a long list of calibration parameter values,  
                   these should be ordered first (fastest) by pol (if pol!=’’),  
                   then by antenna (if antenna!=’’), and finally (sloweset) by  
                   spw (if spw!=’’).  Unspecified selection axes must not be  
                   enumerated in the parameter list  
 
     Examples:  
 
       gencal(vis=’test.ms’,caltable=’test.G’,caltype=’amp’,  
              spw=’’,antenna=’’,pol=’’,  
              parameter=[3])  
 
         --> Antenna-based gain amplitude corrections for all spws, antennas,  
              and polarizations will be multiplied by 3.  When applied  
              to visibility data, this correction will produce a  
              corrected visibility than is (1/3*1/3) less than the  
              uncorrected visibility.  
 
       gencal(vis=’test.ms’,caltable=’test.G’,caltype=’ph’,  
              spw=’’,antenna=’ea03,ea04’,pol=’’,  
              parameter=[45,120])  
 
         --> Gain phase corrections for antennas ea03 and ea04  
              will be adjusted (additive) by 45 and 120  
              degrees (respectively), for all spws and polarizations.  
              When these phases are applied to visibility data, the  
              visibility phases will decrease or increase by the  
              specified amount where the selected antennas occur  
              first or second (respectively) in each baseline.  E.g.,  
              the phase of baseline ea03-ea04 will change by (-45+120)  
              = + 75 degrees.  Baseline ea01-ea03’s phase will change  
              by +45 degrees; baseline ea04-ea05’s phase will change  
              by -120 degrees.  The same phase sign convention is  
              used for delay and antenna position corrections.  
 
       gencal(vis=’test.ms’,caltable=’test.G’,caltype=’ph’,  
              spw=’’,antenna=’ea05,ea06’,pol=’R’,  
              parameter=[63,-34])  
 
         --> Gain phase corrections for antennas ea05 and ea06  
              will be adjusted (additive) by 63 and -34  
              degrees (respectively), in R only, for all spws  
 
       gencal(vis=’test.ms’,caltable=’test.G’,caltype=’ph’,  
              spw=’’,antenna=’ea09,ea10’,pol=’R,L’,  
              parameter=[14,-23,-130,145])  
 
         --> Gain phase corrections in all spws will be adjusted for  
              antenna ea09 by 14 deg in R and -23 deg in L, and for  
              antenna ea10 by -130 deg in R and 145 deg in L.  
 
       gencal(vis=’test.ms’,caltable=’test.G’,caltype=’ph’,  
              spw=’2,3’,antenna=’ea09,ea10’,pol=’’,  
              parameter=[14,-23,-130,145])  
 
         --> Gain phases corrections in both polarizations will be adjusted for  
              antenna ea09 by 14 deg in spw 2 and -23 deg in spw 3, and for  
              antenna ea10 by -130 deg in spw 2 and 145 deg in spw 3.  
 
       gencal(vis=’test.ms’,caltable=’test.G’,caltype=’sbd’,  
              spw=’2,3’,antenna=’ea09,ea10’,pol=’’,  
              parameter=[14,-23,-130,145])  
 
         --> Delay corrections in both polarizations will be adjusted for  
              antenna ea09 by 14 nsec in spw 2 and -23 nsec in spw 3, and for  
              antenna ea10 by -130 nsec in spw 2 and 145 nsec in spw  
              3.  See the above example for caltype=’ph’ for details  
              of the sign convention adopted when applying delay corrections.  
 
       gencal(vis=’test.ms’,caltable=’test.G’,caltype=’antpos’,antenna=’’)  
 
         --> *** Currently EVLA observations only ***  
             Antenna position corrections will be retrieved automatically  
             over internet to generate the caltable with antenna=’’.  
 
       gencal(vis=’test.ms’,caltable=’test.G’,caltype=’antpos’,  
              antenna=’ea09,ea10’,  
              parameter=[0.01,0.02,0.03, -0.03,-0.01,-0.02])  
 
         --> Antenna position corrections in meters (in ITRF) for  
              antenna ea09 (dBx=0.01, dBy=0.02, dBz=0.03) and for  
              antenna ea10 (dBx=-0.03, dBy=-0.01, dBz=-0.02)  
              See the above example for caltype=’ph’ for details  
              of the sign convention adopted when applying antpos  
              corrections.  
 
       gencal(vis=’test.ms’,caltable=’test.G’,caltype=’antposvla’,  
              antenna=’ea09,ea10’,  
              parameter=[0.01,0.02,0.03, -0.03,-0.01,-0.02])  
 
         --> Antenna position corrections (in the traditional VLA-centric  
              frame) will be introduced in meters for  
              antenna ea09 (dBx=0.01, dBy=0.02, dBz=0.03) and for  
              antenna ea10 (dBx=-0.03, dBy=-0.01, dBz=-0.02)  
              These offsets will be rotated to the ITRF frame before  
              storing them in the caltable.  
              See the above example for caltype=’ph’ for details  
              of the sign convention adopted when applying antpos  
              corrections.  
 


More information about CASA may be found at the CASA web page

Copyright © 2016 Associated Universities Inc., Washington, D.C.

This code is available under the terms of the GNU General Public Lincense


Home | Contact Us | Directories | Site Map | Help | Privacy Policy | Search