NRAO Home > CASA > CASA Task Reference Manual

0.1.33 gaincal

Requires:

Synopsis
Determine temporal gains from calibrator observations

Description

The complex gains for each antenna/spwid are determined from the data column (raw data), divided by the model column, for the specified fields. The gains can be obtained for a specified solution interval for each spectral window, or by a spline fit to all spectral windows simultaneously.

Previous calibrations (egs. bandpass) should be applied on the fly.



Arguments





Inputs

vis

Name of input visibility file

allowed:

string

Default:

caltable

Name of output gain calibration table

allowed:

string

Default:

field

Select field using field id(s) or field name(s)

allowed:

string

Default:

spw

Select spectral window/channels

allowed:

string

Default:

intent

Select observing intent

allowed:

string

Default:

selectdata

Other data selection parameters

allowed:

bool

Default:

True

timerange

Select data based on time range

allowed:

string

Default:

uvrange

Select data within uvrange (default units meters)

allowed:

any

Default:

variant

antenna

Select data based on antenna/baseline

allowed:

string

Default:

scan

Scan number range

allowed:

string

Default:

observation

Select by observation ID(s)

allowed:

any

Default:

variant

msselect

Optional complex data selection (ignore for now)

allowed:

string

Default:

solint

Solution interval: egs. ’inf’, ’60s’ (see help)

allowed:

any

Default:

variant inf

combine

Data axes which to combine for solve (obs, scan, spw, and/or field)

allowed:

string

Default:

preavg

Pre-averaging interval (sec) (rarely needed)

allowed:

double

Default:

-1.0

refant

Reference antenna name(s)

allowed:

string

Default:

minblperant

Minimum baselines _per antenna_ required for solve

allowed:

int

Default:

4

minsnr

Reject solutions below this SNR

allowed:

double

Default:

3.0

solnorm

Normalize average solution amplitudes to 1.0 (G, T only)

allowed:

bool

Default:

False

gaintype

Type of gain solution (G,T,GSPLINE,K,KCROSS)

allowed:

string

Default:

G

smodel

Point source Stokes parameters for source model.

allowed:

doubleArray

Default:

calmode

Type of solution: (’ap’, ’p’, ’a’)

allowed:

string

Default:

ap

append

Append solutions to the (existing) table

allowed:

bool

Default:

False

splinetime

Spline timescale(sec); All spw’s are first averaged.

allowed:

double

Default:

3600.0

npointaver

The phase-unwrapping algorithm

allowed:

int

Default:

3

phasewrap

Wrap the phase for jumps greater than this value (degrees)

allowed:

double

Default:

180.0

docallib

Use callib or traditional cal apply parameters

allowed:

bool

Default:

False

callib

Cal Library filename

allowed:

string

Default:

gaintable

Gain calibration table(s) to apply on the fly

allowed:

stringArray

Default:

gainfield

Select a subset of calibrators from gaintable(s)

allowed:

stringArray

Default:

interp

Temporal interpolation for each gaintable (”=linear)

allowed:

stringArray

Default:

spwmap

Spectral windows combinations to form for gaintables(s)

allowed:

intArray

Default:

parang

Apply parallactic angle correction on the fly

allowed:

bool

Default:

False

Example

 
 
      The complex gains for each antenna/spwid are determined from the  
      data column (raw data) divided by the model column.  The gains can  
      be obtained for a specified solution interval, spw combination and  
      field combination.  The GSPLINE spline (smooth) option is still under  
      development.  
 
      Previous calibrations (egs, bandpass, opacity, parallactic angle) can  
      be applied on the fly.  At present with dual-polarized data, both  
      polarizations must be unflagged for any solution to be obtained.  
 
      Keyword arguments:  
      vis -- Name of input visibility file  
              default: none; example: vis=’ngc5921.ms’  
      caltable -- Name of output gain calibration table  
              default: none; example: caltable=’ngc5921.gcal’  
 
      --- Data Selection (see help par.selectdata for more detailed information)  
 
      field -- Select field using field id(s) or field name(s).  
                 [’go listobs’ to obtain the list id’s or names]  
              default: ’’=all fields  
              If field string is a non-negative integer, it is assumed a  
                field index,  otherwise, it is assumed a field name  
              field=’0~2’; field ids 0,1,2  
              field=’0,4,5~7’; field ids 0,4,5,6,7  
              field=’3C286,3C295’; field named 3C286 and 3C295  
              field = ’3,4C*’; field id 3, all names starting with 4C  
          DON’T FORGET TO INCLUDE THE FLUX DENSITY CALIBRATOR IF YOU HAVE ONE  
      spw -- Select spectral window/channels  
               type ’help par.selection’ for more examples.  
             spw=’0~2,4’; spectral windows 0,1,2,4 (all channels)  
             spw=’<2’;  spectral windows less than 2 (i.e. 0,1)  
             spw=’0:5~61’; spw 0, channels 5 to 61, INCLUSIVE  
             spw=’*:5~61’; all spw with channels 5 to 61  
             spw=’0,10,3:3~45’; spw 0,10 all channels, spw 3, channels 3 to 45.  
             spw=’0~2:2~6’; spw 0,1,2 with channels 2 through 6 in each.  
             spw=’0:0~10;15~60’; spectral window 0 with channels 0-10,15-60  
                       NOTE ’;’ to separate channel selections  
             spw=’0:0~10^2,1:20~30^5’; spw 0, channels 0,2,4,6,8,10,  
                   spw 1, channels 20,25,30  
      intent -- Select observing intent  
                default: ’’  (no selection by intent)  
                intent=’*BANDPASS*’  (selects data labelled with  
                                      BANDPASS intent)  
      selectdata -- Other data selection parameters  
              default: True  
 
              Must set selectdata=True to use the following selections:  
 
      timerange  -- Select data based on time range:  
              default = ’’ (all); examples,  
              timerange = ’YYYY/MM/DD/hh:mm:ss~YYYY/MM/DD/hh:mm:ss’  
              Note: if YYYY/MM/DD is missing date defaults to first day in data set  
              timerange=’09:14:0~09:54:0’ picks 40 min on first day  
              timerange= ’25:00:00~27:30:00’ picks 1 hr to 3 hr 30min on NEXT day  
              timerange=’09:44:00’ pick data within one integration of time  
              timerange=’>10:24:00’ data after this time  
      uvrange -- Select data within uvrange (default units meters)  
              default: ’’ (all); example:  
              uvrange=’0~1000klambda’; uvrange from 0-1000 kilo-lambda  
              uvrange=’>4klambda’;uvranges greater than 4 kilo lambda  
      antenna -- Select data based on antenna/baseline  
              default: ’’ (all)  
              If antenna string is a non-negative integer, it is assumed an  
                antenna index, otherwise, it is assumed as an antenna name  
              antenna=’5&6’; baseline between antenna index 5 and index 6.  
              antenna=’VA05&VA06’; baseline between VLA antenna 5 and 6.  
              antenna=’5&6;7&8’; baselines with indices 5-6 and 7-8  
              antenna=’5’; all baselines with antenna index 5  
              antenna=’05’; all baselines with antenna number 05 (VLA old name)  
              antenna=’5,6,10’; all baselines with antennas 5,6,10 index numbers  
      scan -- Scan number range.  
              Check ’go listobs’ to insure the scan numbers are in order.  
      observation -- Observation ID(s).  
                     default: ’’ = all  
                     example: ’0~2,4’  
      msselect -- Optional complex data selection (ignore for now)  
 
      --- Solution parameters  
      gaintype -- Type of gain solution (G, T, or GSPLINE)  
              default: ’G’; example: gaintype=’GSPLINE’  
              ’G’ means determine gains for each polarization and sp_wid  
              ’T’ obtains one solution for both polarizations;  Hence. their  
                phase offset must be first removed using a prior G.  
              ’GSPLINE’ makes a spline fit to the calibrator data.  It is  
                   useful for noisy data and fits a smooth curve through the  
                   calibrated amplitude and phase.  However,  
                   at present GSPLINE is somewhat experimental.  Use with  
                   caution and check solutions.  
              ’K’ solves for simple antenna-based delays  
                   via FFTs of the spectra on baselines to the  
                   reference antenna.  (This is not global  
                   fringe-fitting.)  If combine includes ’spw’,  
                   multi-band delays are determined; otherwise,  
                   per-spw single-band delays will be determined.  
              ’KCROSS’ solves for a global cross-hand  
                   delay.  Use parang=T and apply prior gain and  
                   bandpass solutions.   Multi-band delay solves  
                   (combine=’spw’) not yet supported for KCROSS.  
      smodel -- Point source Stokes parameters for source model (experimental)  
              default: [] (use MODEL_DATA column)  
              example: [1,0,0,0] (I=1, unpolarized)  
      calmode -- Type of solution  
              default: ’ap’ (amp and phase); example: calmode=’p’  
              Options: ’p’,’a’,’ap’  
      solint --  Solution interval (units optional)  
              default: ’inf’ (~infinite, up to boundaries controlled by combine);  
              Options: ’inf’ (~infinite),  
                       ’int’ (per integration)  
                       any float or integer value with or without units  
              examples: solint=’1min’; solint=’60s’; solint=60 --> 1 minute  
                        solint=’0s’; solint=0; solint=’int’ --> per integration  
                        solint-’-1s’; solint=’inf’ --> ~infinite, up to boundaries  
                        interacts with combine  
      combine -- Data axes to combine for solving  
              default: ’’ --> solutions will break at obs, scan, field, and spw  
                      boundaries  
              Options: ’’,’obs’,’scan’,’spw’,field’, or any comma-separated  
                       combination in a single string  
              For gaintype=’K’, if combine includes ’spw’, multi-band  
               delays will be determined; otherwise, (per-spw)  
               single-band delays will be determined.  
              example: combine=’scan,spw’  --> extend solutions over scan boundaries  
                       (up to the solint), and combine spws for solving  
      refant -- Reference antenna name(s); a prioritized list may be specified  
              default: ’’ => no refant applied  
              example: refant=’4’ (antenna with index 4)  
                       refant=’VA04’ (VLA antenna #4)  
                       refant=’EA02,EA23,EA13’ (EVLA antenna EA02, use  
                                EA23 and EA13 as alternates if/when EA02  
                                drops out)  
              Use taskname=listobs for antenna listing  
      minblperant --  Minimum number of baselines required per antenna for each solve  
              default = 4  
              Antennas with fewer baaselines are excluded from solutions.  
              example: minblperant=10  => Antennas participating on 10 or more  
                       baselines are included in the solve  
              minblperant = 1 will solve for all baseline pairs, even if only  
                   one is present in the data set.  Unless closure errors are  
                   expected, use taskname=gaincal rather than taskname=blcal to  
                   obtain more options in data analysis.  
      minsnr -- Reject solutions below this SNR  
              default: 3.0  
      solnorm -- Normalize average solution amps to 1.0 after solution (G, T only)  
              default: False (no normalization)  
      append -- Append solutions to the (existing) table.  Appended solutions  
                 must be derived from the same MS as the existing  
                 caltable, and solution spws must have the same  
                 meta-info (according to spw selection and solint)  
                 or be non-overlapping.  
              default: False; overwrite existing table or make new table  
      splinetime -- Spline timescale (sec); used for gaintype=’GSPLINE’  
              default: 3600 (1 hour); example: splinetime=1000  
              Typical splinetime should cover about 3 to 5 calibrator scans.  
      npointaver -- Tune phase-unwrapping algorithm for gaintype=’GSPLINE’  
              default: 3; Keep at this value  
      phasewrap -- Wrap the phase for changes larger than this amoun (degrees)  
              default: 180; Keep at this value  
 
      --- Other calibrations to apply on the fly before determining gaincal solution  
 
      docallib -- Control means of specifying the caltables:  
               default: False ==> Use gaintable,gainfield,interp,spwmap,calwt  
                        If True, specify a file containing cal library in callib  
      callib -- If docallib=True, specify a file containing cal  
                  library directives  
 
      gaintable -- Gain calibration table(s) to apply  
               default: ’’ (none);  
               examples: gaintable=’ngc5921.gcal’  
                         gaintable=[’ngc5921.ampcal’,’ngc5921.phcal’]  
      gainfield -- Select a subset of calibrators from gaintable(s) to apply  
               default:’’ ==> all sources in table;  
               ’nearest’ ==> nearest (on sky) available field in table  
               otherwise, same syntax as field  
               example: gainfield=’0~2,5’ means use fields 0,1,2,5 from gaintable  
                        gainfield=[’0~3’,’4~6’] means use field 0 through 3  
                          from first gain file, field 4 through 6 for second.  
      interp -- Interpolation type (in time[,freq]) to use for each gaintable.  
                When frequency interpolation is relevant (B, Df, Xf),  
                separate time-dependent and freq-dependent interp  
                types with a comma (freq _after_ the comma).  
                Specifications for frequency are ignored when the  
                calibration table has no channel-dependence.  
                Time-dependent interp options ending in ’PD’ enable a  
                "phase delay" correction per spw for non-channel-dependent  
                calibration types.  
                For multi-obsId datasets, ’perobs’ can be appended to  
                the time-dependent interpolation specification to  
                enforce obsId boundaries when interpolating in time.  
                default: ’’ --> ’linear,linear’ for all gaintable(s)  
                example: interp=’nearest’   (in time, freq-dep will be  
                                             linear, if relevant)  
                         interp=’linear,cubic’  (linear in time, cubic  
                                                 in freq)  
                         interp=’linearperobs,spline’ (linear in time  
                                                       per obsId,  
                                                       spline in freq)  
                         interp=’,spline’  (spline in freq; linear in  
                                            time by default)  
                         interp=[’nearest,spline’,’linear’]  (for multiple gaintables)  
                Options: Time: ’nearest’, ’linear’  
                         Freq: ’nearest’, ’linear’, ’cubic’, ’spline’  
      spwmap -- Spectral windows combinations to form for gaintable(s)  
                default: [] (apply solutions from each spw to that spw only)  
                Example:  spwmap=[0,0,1,1] means apply the caltable solutions  
                          from spw = 0 to the spw 0,1 and spw 1 to spw 2,3.  
                          spwmap=[[0,0,1,1],[0,1,0,1]]  
      parang -- If True, apply the parallactic angle correction (required  
               for polarization calibration)  
               default: False  
      preavg -- Pre-averaging interval (sec)  
              default=-1 (none).  
               Rarely needed.  Will average data over periods shorter than  
                 the solution interval first.  
      async --  Run asynchronously  
              default = False; do not run asychronously  


More information about CASA may be found at the CASA web page

Copyright © 2016 Associated Universities Inc., Washington, D.C.

This code is available under the terms of the GNU General Public Lincense


Home | Contact Us | Directories | Site Map | Help | Privacy Policy | Search