Dec 9, 2004

L301 Status



#1
Functioning Normally. (Miteq Breadboard-in-a-box version)  LO
#2
Functioning Normally. (Miteq Hybrid version 1/2 Production / 1/2 Discrete RF section) EA13-L301-2
#3
Functioning Normally. (Miteq AGC / Norden Hybrid version 1/2 Production / 1/2 Discrete RF section) ATR-L301-?
#4
Functioning Normally. (Norden Hybrid version 1/2 Production / 1/2 Discrete RF section) (note 2) LO
#5
Production  version  depends on  Delivery of AGC subassy from Miteq.  Planned for Jan 1, 2005 NA
#6
Production  version  depends on  Delivery of AGC subassy from Miteq.  Planned for Jan 1, 2005
NA

L302 Status



#1
Functioning Normally. Main DDS sample output added for phase testing. (Miteq Breadboard-in-a-box version)  EA13-L302-1
#2
(Miteq Hybrid version 1/2 Production / 1/2 Discrete RF section) NO MIB LO
#3
Functioning Normally. (Norden Hybrid version 1/2 Production / 1/2 Discrete RF section) MIB 58
Chamber
#4
Functioning Normally. (Norden Hybrid version 1/2 Production / 1/2 Discrete RF section) High Phase Noise & Spurs present in test rack - not seen on bench. EA14-L302-?
#5
Functioning Normally. (Norden Hybrid version 1/2 Production / 1/2 Discrete RF section) (no comb filter) (note 2) MIB 59
Chamber
#6
Functioning Normally. (Norden Hybrid version 1/2 Production / 1/2 Discrete RF section) (no comb filter) (note 2) NO MIB LO
#7
Functioning Normally. (Miteq Hybrid version 1/2 Production / 1/2 Discrete RF section) (no comb filter) (note 2)
ATR-L302-?
#8
Production  version  depends on  Delivery of AGC subassy from Miteq.  Planned for Jan 1, 2005 NA
#9
Production  version  depends on  Delivery of AGC subassy from Miteq.  Planned for Jan 1, 2005 NA
#10
Production  version  depends on  Delivery of AGC subassy from Miteq.  Planned for Jan 1, 2005 NA
#11
Production  version  depends on  Delivery of AGC subassy from Miteq.  Planned for Jan 1, 2005 NA

Legend:

Done, Pending, Late or repairing, EAxx= Antenna xx, ATR= Antenna Test Rack, LO= Synth Lab, NA= Not built.

Hybrid means that the synthesizer has discrete RF componenets and a production motherboard, PLL's, monitor interface, and DDS boards.  The discrete RF components will be replaced with an integrated subassembly.

Notes:

1.  All synthesizers on antennas are limited to 2 telnet sessions.  Unlimited monitoring possible w/Moeser software.
2.  Synths without comb filter may not function optimally.  Check with Synth lab for details.
3.  These modules will be updated to the new form factor as time and schedule permit.  Will remain discrete RF sections.