OPSLEWTI

OPSLEWTI is the parameter for OPTMODE=HAS that is used to normalize the weighting based on slew time. The slew time weight is set by the equation:

 SLEWWT = MAX(0.0,OPSLEWWT(JSCN)*(1.0-OPSLEW/OPSLEWTI(JSCN)))
Where OPSLEW is the difference between the stop time of the previous scan and the time when all antennas are ready to observe the scan being tested.

See the discussion of the possible optimization modes in the section on OPTMODE for more information on OPTMODE=HAS